DTC · AdBlue or SCR message

Fault code P20EE — SCR efficiency below threshold

The control unit reports insufficient NOx conversion efficiency under the monitored conditions. A simple low level does not describe the same fault.

What to do with the code P20EE?

Examine associated faults and verify consistency of NOx measurements, dosage and operating conditions. A Volkswagen note highlights the quality of AdBlue on the Touareg in question. The code alone does not confirm a faulty pump or catalyst.

Documented brands and versions

Touareg II 3.0 TDI

North American Volkswagen note targeting the 3.0 TDI CNRB 2011–2016. Within the scope of the site, retain 2013–2016 for this documented engine.

Audi Q7 TDI, first generation

Audi bulletin on certain first generation Q7 TDIs. Check the vehicle and the complete wording.

A document published for another market is a technical benchmark. Check its scope and the version of your car before applying a bulletin or requesting support.

Send a useful report to the workshop

Keep the complete code, the name of the control unit, the year and the engine. If multiple faults are present, send the entire report with dashboard text and recent interventions. Follow the manual and stopping instructions displayed by your car.

LET'S TALK ABOUT YOUR CAR

Any doubts?
Let's start by talking about it.

Specify the model, year and your needs.

Write on WhatsApp ↗Prepare an appointment request

Garage Rabat
M125 CYN, Avenue Al Majd, Rue Al Falah, Amal 5, Rabat 10052
Monday–Saturday: 09:00–19:30

Technical background: how it works, causes and checks

P20EE reports insufficient nitrogen oxide (NOx) conversion efficiency in the SCR catalyst. One NOx sensor upstream and one downstream let the control unit compare the NOx level before and after the AdBlue injection; if the reduction stays below the expected threshold, the code is stored.

Possible technical causes

  • Poor-quality, diluted or expired AdBlue: the ISO 22241 standard targets a 32.5 % urea solution.
  • Injector or doser partly blocked by urea crystals.
  • Aged or contaminated SCR catalyst.
  • Drifting upstream or downstream NOx sensor.
  • Exhaust leak between the engine and the catalyst, or a fouled mixer.

Checks carried out in the workshop

  • Read both NOx sensor values and the dosing rate.
  • Check AdBlue concentration with a refractometer.
  • Test the doser flow and inspect it for crystal deposits.
  • Look for an exhaust leak upstream of the catalyst.

Key point: A low AdBlue level does not describe this fault: the tank can be full and the code still present. No deactivation of the SCR system is offered.

Automatically translated from French using Google Translate. Confirm technical details with the workshop. Version française