DTC · AdBlue or SCR message

Fault code P229F00 — NOx sensor 2 reading

Audi describes this variation as a deviation in range or performance of the signal from NOx sensor number 2. The position and wording should be read on the report.

What to do with the code P229F00?

Before replacement, check the circuit, signal and operating context of the SCR. Specify if a sensor has already been changed and at what position. The suffix is ​​part of the reference; don't remove it from the request.

Documented brands and versions

Audi Q7 TDI, first generation

Audi bulletin on certain first generation Q7 TDIs. Check the vehicle and the complete wording.

A document published for another market is a technical benchmark. Check its scope and the version of your car before applying a bulletin or requesting support.

Send a useful report to the workshop

Keep the complete code, the name of the control unit, the year and the engine. If multiple faults are present, send the entire report with dashboard text and recent interventions. Follow the manual and stopping instructions displayed by your car.

LET'S TALK ABOUT YOUR CAR

Any doubts?
Let's start by talking about it.

Specify the model, year and your needs.

Write on WhatsApp ↗Prepare an appointment request

Garage Rabat
M125 CYN, Avenue Al Majd, Rue Al Falah, Amal 5, Rabat 10052
Monday–Saturday: 09:00–19:30

Technical background: how it works, causes and checks

P229F is defined as an abnormal range or performance of the signal from NOx sensor No. 2, located downstream of the SCR catalyst on bank 1. This sensor measures the NOx leaving the system, and its signal is used to verify dosing efficiency. The 00 suffix is the variant stored by Audi.

Possible technical causes

  • Downstream NOx sensor drifting, fouled or at the end of its life.
  • Damaged sensor harness or connector, often near the hot exhaust.
  • Faulty sensor electronics module.
  • Exhaust leak near the sensor distorting the measurement.
  • Upstream dosing problem (AdBlue, doser) that really changes the NOx.

Checks carried out in the workshop

  • Compare the upstream and downstream NOx sensor signals under known conditions.
  • Check the harness, connector and supply of the sensor.
  • Look for an exhaust leak near the sensor location.
  • Check dosing and AdBlue quality before replacing the sensor.

Key point: The exact position and wording are read from the full report. Replacing the sensor without measuring dosing may leave the real fault untouched.

Automatically translated from French using Google Translate. Confirm technical details with the workshop. Version française